2700btu telecom enclosure Air Conditioner- DC48V 800W Air Conditioner

2700btu telecom enclosure Air Conditioner- DC48V 800W Air Conditioner

Model : RODDC800W-48V


The outdoor enclosure air conditioner is designed for controlling the climate of equipment in these off-grid sites with challenging indoor and outdoor environments. With the true DC compressor and DC fans, it effectively solves the heat problem of indoor/outdoor cabinet and is the good choice for the base stations with renewable power or Hybrid power in the off-grid sites.

  • DC48V power input
  • 800W cooling capacity
  • Compact sizing for limited space mounting
  • Energy saving
  • Environmental friendly – R134a and RoHS compliant
  • RS485 for remote control
  • Painted galvanized sheet-metal or stainless steel cover for rugged factory and outdoor environments
  • Easy-mount flanges for simple installation
  • Every unit functionally tested before shipping


RODAC800W-48V Features

The outdoor cabinet air conditioner is actively cooling with compressor, and it will remove the heat inside the cabinet to outside. It also can keep the dust and heat outside the cabinet, avoiding problems from using fan. The inside cabinet can be maintained at an ideal temperature for electrical components which effectively guarantees the stability of the electronic equipment and improves the reliability of the whole system.

AZE offers an extended line of Outdoor Cabinet Air Conditioner solutions. Extend the life expectancy and increase the performance of equipment housed in NEMA type outdoor enclosures. Climate control of sensitive technological equipment allows for longer life expectancy and reduces the necessity of service hours and operational downtime. Our engineering team can assist in calculating the perfect solution based upon variables such as environmental challenges, climates, and the sensitivity of the electronics/hardware being housed.

Key Features  
IP (Ingress Protection) Rating IP55,NEMA 4,NEMA 4X
Power Option DC48V
Cooling Capacity 800W/2700BTU

Includes: power cord(or regional power cords such as UK, EU,ANZ,etc),Installation guide and hardwares

 

Features & Benefits

Energy Efficiency  
Fans,Compressor True 48VDC compressor and fans, no inverter, speed adjustable with long life time and minimal power consumption for energy saving.
Condensor Aluminum micro channel condensor,more efficient
Soft Starting  Soft starting to avoid the inrush current to shut down the site.
Environment friendly R134a refrigerant, compliance with RoHS 
   
Easy Installation and Operation   
Structure design Constructed of glavanized steel,powder coating with RAL7035 excellent anti-corrosion and anti-rust in harsh environment
Mounting methods Designed with flange for convenient through door/wall mounting with outdoor cabinet
IP Grade IP55, NEMA 4 or NEMA 4X, closed loop cooling protects equipment against dust and water.
Plug-play  Compact,plug and play unit to ensure easy installation
IP Grade IP55, NEMA 4 or NEMA 4X
   
Compatiblity and Intelligent Controller  
Power option Compatibility with PDUs- basic rack PDU or intelligentrack PDU,provide the device powering or remotely metering,switching the outlet to control devices
Cooling option Provides 300W to 3500W cooling capacity
Control option  RS485 inteface with MODBUS protocol for remote control
Monitor option  Compatibility with EMS to monitor the site environment such as temperature,humudity,door open/close status,alarm,etc.
Display LCD Menu display

Specification

Model  
Outdoor Model RODDC800W-48V
   
Enclosure Protection  
IP (Ingress Protection) Rating IP55,NEMA 4,NEMA 4X
   
Physical  
Color GREY RAL7035 or customize color
Material Galvanized sheet metal standard(Stainless steel optional)
Sound Level (dBA) 55
Mount method Door mounted
Dimension(WxDxH) 13.9inches x 6.50inches x 22.95inches /353mm x 165mm x 583mm
Weight(lbs./Kgs) 35.26lbs./16 Kgs
   
Cooling Performance  
Norminal Cooling Capacity(Watts) 800
Norminal Cooling Capacity(BTU/Hr) 2731.2
Refrigerant R134a
Operating Temperature -41°F to 131°F/-104°F to 131°F(with heater)
Heating Capacity(Optional) 200W
   
Electrial Data  
Rated Voltage -48VDC
Power Consumption(L35/L35)(Watts) 260
Power Consumption(L35/L55)(Watts) 320
Rated Current(A) 5.4
Starting Current(A) From 1A to rated current
   
Main Electrical Components  
Exhaust Fans Large airflow,low noise
Controller High precision for temperature controller
Compressor High-efficiency ratio,stable performance
Condensor Powerful heat dispation function
Evaporator Fast cooling, dehumidification function
Monitoring EMS,KVM Switches,Smart PDU
   
Certifications  
Approvals RoHS
Safety CE
   
Warranty  
Standard warranty 1 Year 

How to Order

Model Nominal Voltage Rated Current Starting Current Nominal Cooling Capacity(Btu/hr) Nominal Cooling Capacity( Watts) Power Consumption(L35/L35)Watts) Power Consumption(L35/L55)Watts) Sound Level(dBA) Dimension(WxDxH)
RODDC300W-24V -24VDC 6A From 1A to rated current 1020 300 150 185 55 10.39inches x 4.37inches x 17.52inches /264mm x 111mm x 445mm
RODDC400W-24V -24VDC 6.25A From 1A to rated current 1360 400 150 185 55 10.39inches x 4.37inches x 17.52inches /264mm x 111mm x 445mm
RODDC500W-24V -24VDC 6.5A From 1A to rated current 1700 500 150 185 55 10.39inches x 4.37inches x 17.52inches /264mm x 111mm x 445mm
RODDC300W-48V -48VDC 2.7A From 1A to rated current 1020 300 130 160 55 13.9inches x 6.50inches x 22.95inches /353mm x 165mm x 583mm
RODDC400W-48V -48VDC 3.5A From 1A to rated current 1360 400 170 210 55 13.9inches x 6.50inches x 22.95inches /353mm x 165mm x 583mm
RODDC500W-48V -48VDC 4.4A From 1A to rated current 1700 500 215 280 56 13.9inches x 6.50inches x 22.95inches /353mm x 165mm x 583mm
RODDC600W-48V -48VDC 5A From 1A to rated current 2040 600 240 280 56 13.9inches x 6.50inches x 22.95inches /353mm x 165mm x 583mm
RODDC800W-48V -48VDC 5.4A From 1A to rated current 2720 800 260 320 60 13.9inches x 6.50inches x 22.95inches /353mm x 165mm x 583mm
RODDC1000W-48V -48VDC 5.8A From 1A to rated current 3400 1000 280 380 58 19.33inches x 7.36inches x 31.14inches /491mm x 187mm x 791mm
RODDC1200W-48V -48VDC 6.8A From 1A to rated current 4080 1200 325 400 58 19.33inches x 7.36inches x 31.14inches /491mm x 187mm x 791mm
RODDC1500W-48V -48VDC 8.2A From 1A to rated current 5100 1500 395 490 63 19.33inches x 7.36inches x 31.14inches /491mm x 187mm x 791mm
RODDC2000W-48V -48VDC 10.8A From 1A to rated current 6800 2000 520 630 68 18.39inches x 8.98inches x 42.01inches /467mm x 228mm x 1067mm
RODDC2500W-48V -48VDC 12.7A From 1A to rated current 8500 2500 610 740 68 18.39inches x 8.98inches x 42.01inches /467mm x 228mm x 1067mm
RODDC3000W-48V -48VDC 16.25A From 1A to rated current 10200 3000 780 945 70 18.39inches x 8.98inches x 42.01inches /467mm x 228mm x 1067mm
RODDC3500W-48V -48VDC 18.75A From 1A to rated current 11900 3500 900 1100 70 20inches x 8.62inches x 45.94inches /508mm x 219mm x 1167mm

 

**********Notes**********

No.
Item
Specifications
1
AC110V or 220V/DC48V, Cooling Capacity 300W-5000W
2
DC48V, Heat transfer 40W/K-200W/K
3
DC48V, Cooling capacity 100W-300W
4
Fan
AC110/220V or DC 48V 

Options


Application

The outdoor cabinet air conditioner is designed to cool your electronic and electrical controls, telecommunications equipment, surveillance devices and many other electronics in variety of environments.

  • Wireless communication cabinet
  • Battery cabinet
  • Industry control cabinet
  • Outdoor hybrid base station
  • Outdoor battery cabinet
  • Wireless outdoor cabinet 

Related Article

KVM Switches Buying Guide

A KVM (Keyboard, Video, and Mouse) Switch is a device that allows you to control multiple computers from a single keyboard, video monitor and mouse console.

Integrated Outdoor Enclosures Solutions

We supply Integrated Outdoor Enclosures Solutions for your projects.

What is a Colocation Data Center

What is a Colocation Data Center?

How to Choose the Right Rack PDU for Data Centers

Rack PDU is a critical part for your IT environment.

GET A QUOTE